C
HAPTER
27
| Interface Commands
Transceiver Threshold Configuration
– 990 –
DEFAULT SETTING
Disabled
COMMAND MODE
Interface Configuration (Ethernet)
EXAMPLE
Console(config)interface ethernet 1/25
Console(config-if)#transceiver-threshold-auto
Console#
transceiver-monitor This command sends a trap when any of the transceiver’s operational
values fall outside of specified thresholds. Use the no form to disable trap
messages.
SYNTAX
transceiver-monitor
DEFAULT SETTING
Disabled
COMMAND MODE
Interface Configuration (Ethernet)
EXAMPLE
Console(config)interface ethernet 1/25
Console(config-if)#transceiver-monitor
Console#
transceiver-
threshold current
This command sets thresholds for transceiver current which can be used to
trigger an alarm or warning message.
SYNTAX
transceiver-threshold current {high-alarm | high-warning |
low-alarm | low-warning} threshold-value
high-alarm – Sets the high current threshold for an alarm
message.
high-warningSets the high current threshold for a warning
message.
low-alarm – Sets the low current threshold for an alarm message.
low-warningSets the low current threshold for a warning
message.
threshold-value – The threshold of the transceiver current.
(Range: 0-13100 in units of 0.01 mA)