C
HAPTER
20
| System Management Commands
Time Range
– 763 –
time-range This command specifies the name of a time range, and enters time range
configuration mode. Use the no form to remove a previously specified time
range.
SYNTAX
[no] time-range name
name - Name of the time range. (Range: 1-16 characters)
DEFAULT SETTING
None
COMMAND MODE
Global Configuration
COMMAND USAGE
This command sets a time range for use by other functions, such as Access
Control Lists.
EXAMPLE
Console(config)#time-range r&d
Console(config-time-range)#
RELATED COMMANDS
Access Control Lists (951)
absolute This command sets the time range for the execution of a command. Use
the no form to remove a previously specified time.
SYNTAX
absolute start hour minute day month year
[end hour minutes day month year]
absolute end hour minutes day month year
no absolute
hour - Hour in 24-hour format. (Range: 0-23)
minute - Minute. (Range: 0-59)
day - Day of month. (Range: 1-31)
month - january | february | march | april | may | june | july |
august | september | october | november | december
year - Year (4-digit). (Range: 2009-2109)
DEFAULT SETTING
None