EasyManua.ls Logo

Edge-Core ES3528MV2 - Show Ethernet Cfm Configuration

Edge-Core ES3528MV2
1480 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C
HAPTER
41
| CFM Commands
Defining CFM Structures
– 1332
show ethernet cfm
configuration
This command displays CFM configuration settings, including global
settings, SNMP traps, and interface settings.
SYNTAX
show ethernet cfm configuration {global | traps |
interface interface}
globalDisplays global settings including CFM global status, cross-
check start delay, and link trace parameters.
traps – Displays the status of all continuity check and cross-check
traps.
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28)
port-channel channel-id (Range: 1-12)
DEFAULT SETTING
None
COMMAND MODE
Privileged Exec
EXAMPLE
This example shows the global settings for CFM.
Console#show ethernet cfm configuration global
CFM Global Status : Enabled
Crosscheck Start Delay : 10 seconds
Linktrace Cache Status : Enabled
Linktrace Cache Hold Time : 100 minutes
Linktrace Cache Size : 100 entries
Console#
This example shows the configuration status for continuity check and
cross-check traps.
Console#show ethernet cfm configuration traps
CC MEP Up Trap :Disabled
CC MEP Down Trap :Disabled
CC Configure Trap :Disabled
CC Loop Trap :Disabled
Cross Check MEP Unknown Trap :Disabled
Cross Check MEP Missing Trap :Disabled
Cross Check MA Up :Disabled
Console#