C
HAPTER
45
| IP Interface Commands
ND Snooping
– 1437
EXAMPLE
Console#clear ipv6 nd snooping prefix
Console#show ipv6 nd snooping prefix
Prefix entry timeout: (seconds)
Prefix Len Valid-Time Expire VLAN Interface
-------------------------------------- --- ---------- ---------- ---- ---------
Console#
show ipv6 nd
snooping
This command shows the configuration settings for ND snooping.
SYNTAX
show ipv6 nd snooping
COMMAND MODE
Privileged Exec
EXAMPLE
Console#show ipv6 nd snooping
Global ND Snooping status: enabled
ND Snooping auto-detection: disabled
ND Snooping auto-detection retransmit count: 3
ND Snooping auto-detection retransmit interval: 1 (second)
ND Snooping is configured on the following VLANs:
VLAN 1,
Interface Trusted Max-binding
--------- --------- -----------
Eth 1/1 Yes 1
Eth 1/2 No 5
Eth 1/3 No 5
Eth 1/4 No 5
Eth 1/5 No 5
.
.
.
show ipv6 nd
snooping binding
This command shows all entries in the dynamic user binding table.
SYNTAX
show ipv6 nd snooping binding
COMMAND MODE
Privileged Exec
EXAMPLE
Console#show ipv6 nd snooping binding
MAC Address IPv6 Address Lifetime VLAN Interface
-------------- -------------------------------------- ---------- ---- ---------
0013-49aa-3926 2001:b001::211:95ff:fe84:cb9e 100 1 Eth 1/1
0012-cf01-0203 2001::1 3400 2 Eth 1/2
Console#