SmartAXIS Touch User's Manual 3-61
4 Special Functions
3
Project
Procedure
To use the high-speed counter, a normal input must be specified as Two-phase High-speed Counter or Single-
phase High-speed Counter in the Function Area Settings tab. Inputs I0 to I7 on the Touch can be selected as
normal input, high-speed counter, catch input, interrupt input, and frequency measurement.
When using normal input, catch input, interrupt input, or frequency measurement, high-speed counter cannot be
used. The interrupt input can only be used when ladder program is selected as the programming language.
1 On the WindO/I-NV3 View tab, in the Workspace group, click (Control Function).
WindLDR starts.
2 On the WindLDR Configuration tab, in the Function Area Settings group, click Input & Output Configuration.
The Function Area Settings dialog box is displayed.
3
Select
Two-phase High-speed Counter
or
Single-phase High-speed Counter
for the group to use the high-speed counter.
The High-speed Counter Settings dialog box is displayed.
4 Configure the operation mode and the counting mode, and then click OK.
To use comparison actions, configure the comparison settings.
5 Click OK.
This concludes configuring the settings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals