4 Special Functions
3-60 SmartAXIS Touch User's Manual
Comparison operation flow
The comparison operation flow is as follows.
1 Start (Run) the Touch.
For the first scan, Next Preset Value Number is set to the number for preset value 1 with the initialize pulse.
For the second scan, an I/O refresh is performed in END processing and the value of Next Preset Value Number is
transferred to Current Preset Value Number.
The content of Next Preset Value Number becomes the preset value n + 1 ("2" in this example).
When the number of preset values is 1, Next Preset Value Number is always "1".
2 Start the high-speed counter count operation.
Turn on the gate input to start the count operation.
3 Compare the Current Preset Value Number preset value and the current value. When the current value and the
preset value match, the next number for the preset value becomes active and the high-speed counter continues
counting.
Execute Comparison Output or Interrupt Program. (Comparison Output in this example)
• Turn on the comparison (special internal relay) for only one scan.
• Overwrite Current Preset Value Number with Next Preset Value Number and start the count with the preset
value for Current Preset Value Number.
• Add 1 to Next Preset Value Number.
4 When the procedure is executed up to preset value 6, repeat again from the beginning with preset value 1.
Group
Group 1
(I0 to I1)
Read/Write
Preset Value
(Upper word)
D8052
R/W
Preset Value
(Lower word)
D8053
Example: For group 1
Storage destination for the preset value that became active.
Stored by group.
The outputs (external outputs) when the values match.
The data register that stores the preset value (target value).
Specify the starting address.
The preset value with the number that became active is
the comparison subject with the current value and is
stored in the special data registers.
Transfer
The Current Preset Value Number data register cannot be written to. It is read-only.
Next Preset Value Number and Preset Value 1 to Preset Value 6 can be read and written to.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals