5 Script Coding Examples
20-44 SmartAXIS Touch User’s Manual
String operations
When using functions that handle string data, check the Storage Method of string data setting in the project
settings.
For details, refer to Chapter 3 “3.1 System Tab” on page 3-19.
Script
Operation description
Stores in order from LDR100 character count 3 (3 characters worth) from start position 2 (starting from 0, so the 3rd
character) of the string “ABCDEFG” that starts from LDR200.
Copy from string “ABCDEFG” at start position 2, character count 3
Script
Copy from string “ABCDEFG” at start position 1, character count 4
*2 HMI function only
*2
Example 5.7.29 Copy a string
STRCUT([LDR 100], [LDR 200], 2, 3);
The start position can be specified in the range from 0 to 127, the character count can be specified in the
range from 1 to 128.
STRUCT([LDR 100], [LDR 200], 1, 4);
Device
Stored value
Start
position
Character
count
Device
Stored value
LDR200
Upper byte
'A' = 0x41 0
LDR100
Upper byte
'C' = 0x43
Lower byte
'B' = 0x42 1
Lower byte
'D' = 0x44
LDR201
Upper byte
'C' = 0x43 2
LDR101
Upper byte
'E' = 0x45
Lower byte
'D' = 0x44 3
Lower byte
0x00
Terminating character
LDR202
Upper byte
'E' = 0x45 4
Lower byte
'F' = 0x46 5
LDR203
Upper byte
'G' = 0x47 :
Lower byte
0x00
Terminating character
3 characters
Device
Stored value
Start
position
Character
count
Device
Stored value
LDR200
Upper byte
'A' = 0x41 0
LDR100
Upper byte
'B' = 0x42
Lower byte
'B' = 0x42 1
Lower byte
'C' = 0x43
LDR201
Upper byte
'C' = 0x43 2
LDR101
Upper byte
'D' = 0x44
Lower byte
'D' = 0x44 3
Lower byte
'E' = 0x45
LDR202
Upper byte
'E' = 0x45 4
LDR102
Upper byte
0x00
Terminating character
Lower byte
'F' = 0x46 5
Lower byte
0x00
LDR203
Upper byte
'G' = 0x47 :
Lower byte
0x00
Terminating character
4 characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals