10h1Fh Register Map Detailed DescriptionBCM5718 Programmer’s Guide
Broadcom®
January 29, 2016 5718-PG108-R Page 510
12h: Receive_Error_Counter_Register
9 LOCKED RO 0 1 = descrambler locked
0 = descrambler unlocked
8 LINK_STATUS RO 0 1 = link pass
0 = link fail
7 CRC_ERROR_DETECTED RO LH 0 1 = CRC error detected since last
read
0 = no CRC error detected since
last read
6 CARRIER_EXTENSION_ERROR_DETECTED RO LH 0 1 = carrier ext. error detected
since last read
0 = no carrier ext. error detected
since last read
5 BAD_SSD_DETECTED (FALSE CARRIER) RO LH 0 1 = bad SSD error detected since
last read
0 = no bad SSD error detected
since last read
4 BAD_ESD_DETECTED (PREMATURE END) RO LH 0 1 = bad ESD error detected since
last read
0 = no bad ESD error detected
since last read
3 RECEIVE_ERROR_DETECTED RO LH 0 1 = receive coding error detected
since last read
0 = no receive error detected
since last read
2 TRANSMIT_ERROR_DETECTED RO LH 0 1 = transmit error code detected
since last read
0 = no transmit error detected
since last read
1 LOCK_ERROR_DETECTED RO LH 0 1 = lock error detected since last
read
0 = no lock error detected since
last read
0 MLT3_CODE_ERROR_DETECTED RO LH 0 1 = MLT3 code error detected
since last read
0 = no MLT3 error detected since
last read
Bit Name RW Default Description
15:0 RECEIVE_ERROR_COUNT
ER
RW CR 0000h Number of non-collision packets with receive errors
since last read. Freezes at FFFFh.
(Counts SerDes errors when register 1ch shadow
“11011” bit 9 = 1 otherwise copper errors)