10h1Fh Register Map Detailed DescriptionBCM5718 Programmer’s Guide
Broadcom®
January 29, 2016 5718-PG108-R Page 540
7AUTONEG
RESOLUTION ERROR
RO 1 = autoneg hcd is none (no common half or full
duplex abilities)
0 = SGMII mode, or autoneg disabled, or no
resolution error
0
6:5 LINK PARTNER
REMOTE FAULT
RO 1000-X register 5 [13:12] 00
4AUTONEG PAGE
RECEIVED
RO
LH
1 = page has been received since last read
0 = page has not been received since last read
0
3 CURRENT OPERATING
DUPLEX MODE
RO 1 = phy is operating in full-duplex mode
0 = phy is operating in half-duplex mode (or
auto-negotiation has not completed)
0
2 SERDES LINK RO 1 = link is up for SerDes applications
(SGMII or GBIC mode => both SerDes and
copper must have link for this bit to be set)
0 = link is down for SerDes applications
0
1 PAUSE RESOLUTION
RECEIVE SIDE
RO 1 = enable pause receive
0 = disable pause receive
0
0 PAUSE RESOLUTION
TRANSMIT SIDE
RO 1 = enable pause transmit
0 = disable pause transmit
0
Bit Name RW Description Default