652 | Uplink Failure Detection (UFD)
www.dell.com | support.dell.com
Command
History
Usage
Information
After you enter the command, you enter Uplink-State-Group Configuration mode to assign upstream 
and downstream interfaces to the group.
An uplink-state group is considered to be operationally UP if at least one upstream interface in the 
group is in the Link-Up state.
An Uplink-State group is considered to be operationally DOWN if no upstream interfaces in the group 
are in the link-up state. No uplink-state tracking is performed when a group is disabled or in an 
operationally down state.
Related
Commands
 
Example
Figure 36-4.  uplink-state-group Command Example
upstream 
Assign a port or port-channel to the uplink-state group as an upstream interface.
Syntax
upstream interface
To delete an upstream interface, use the no upstream interface command.
Parameters
 
Defaults
none
Command Modes
UPLINK-STATE-GROUP
Command
History
Usage
Information
You can assign physical port or port-channel interfaces to an uplink-state group.
You can assign an interface to only one uplink-state group. You must configure each interface assigned 
to an uplink-state group as either an upstream or downstream interface, but not both.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
show running-config 
uplink-state-group
Displays the current configuration of one or more uplink-state groups.
show uplink-state-group Displays status information on a specified uplink-state group or all groups.
FTOS(conf)#uplink-state-group 16
FTOS(conf)#
02:23:17: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed uplink state group Admin 
state to up: Group 16
interface Enter one of the following interface types:
10-Gigabit Ethernet: tengigabitethernet {slot/port | slot/port-range}
40-Gigabit Ethernet: fortygigabitethernet {slot/port |slot/port-range}
Port channel: port-channel {1-512 | port-channel-range}
Where port-range and port-channel-range specify a range of ports separated 
by a dash (-) and/or individual ports/port channels in any order; for example:
tengigabitethernet 1/1-2,5,9,11-12
port-channel 1-3,5
A comma is required to separate each port and port-range entry.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module