2 Word Devices
27-16 SmartAXIS Touch User's Manual
D8140 High-Speed Counter (Group 5/I5)
These special data registers are
used with the high-speed counter
function and the frequency
measurement function.
For details, refer to Chapter 3 “4.7
High-Speed Counter” on page 3-55.
Upper Word
Current Value / Frequency
Measurement Value (I5)
Every scan YES YES
D8141 Lower Word
D8142 Upper Word
Preset Value YES YES
D8143 Lower Word
D8144 Upper Word
Reset Value YES YES
D8145 Lower Word
D8146,
8147
Reserved
D8148
Remote I/O Slave 1
Special data registers used by remote I/O.
For details, refer to Chapter 12 “4.2 Remote I/O
Master” on page 12-47.
Connection Error Status
When a
communication
error occurs
YES YES
D8149 Analog input (AI10) Every scan YES YES
D8150 Analog input (AI11) Every scan YES YES
D8151 Analog input (AI12) Every scan YES YES
D8152 Analog input (AI13) Every scan YES YES
D8153 Analog input (AI14) Every scan YES YES
D8154 Analog input (AI15) Every scan YES YES
D8155 Analog input (AI16) Every scan YES YES
D8156 Analog input (AI17) Every scan YES YES
D8157
Remote I/O Slave 2
Special data registers used by remote I/O.
For details, refer to Chapter 12 “4.2 Remote I/O
Master” on page 12-47.
Connection Error Status
When a
communication
error occurs
YES YES
D8158 Analog input (AI20) Every scan YES YES
D8159 Analog input (AI21) Every scan YES YES
D8160 Analog input (AI22) Every scan YES YES
D8161 Analog input (AI23) Every scan YES YES
D8162 Analog input (AI24) Every scan YES YES
D8163 Analog input (AI25) Every scan YES YES
D8164 Analog input (AI26) Every scan YES YES
D8165 Analog input (AI27) Every scan YES YES
D8166
Remote I/O Slave 3
Special data registers used by remote I/O.
For details, refer to Chapter 12 “4.2 Remote I/O
Master” on page 12-47.
Connection Error Status
When a
communication
error occurs
YES YES
D8167 Analog input (AI30) Every scan YES YES
D8168 Analog input (AI31) Every scan YES YES
D8169 Analog input (AI32) Every scan YES YES
D8170 Analog input (AI33) Every scan YES YES
D8171 Analog input (AI34) Every scan YES YES
D8172 Analog input (AI35) Every scan YES YES
D8173 Analog input (AI36) Every scan YES YES
D8174 Analog input (AI37) Every scan YES YES
D8175
Reserved
Device
Address
Description Updated
Ladder
FBD

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals