4 Special Functions
3-56 SmartAXIS Touch User's Manual
High-speed Counter External Inputs
The 12-I/O type can only use a maximum of four single-phase high-speed counters and a maximum of one dual-
phase high-speed counter.
Single-phase high-speed counter
The 12-I/O type cannot use external inputs I0 and I1 as single-phase high-speed counters.
Two-phase high-speed counter
External inputs I0/I1 (group 1) can be used as two-phase high-speed counters. External inputs I2 can be used as
external clear inputs for group 1. In this situation, external inputs I2 cannot be used as single-phase high-speed
counters.
*1 If not used as the external clear input (Z-phase), group 2 can be used as single-phase high-speed counters.
Group 12345
External input I0 I1 I2 I3 I4 I5
Single-phase
high-speed
counter
Pulse input Pulse input Pulse input Pulse input
Group 12345
External input I0 I1 I2 I3 I4 I5
Two-phase
high-speed
counter
Pulse input
(A-phase)
Pulse input
(B-phase)
External clear
input
*1
(Z-phase)
–––

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals