2 Word Write Command
11-14 SmartAXIS Touch User’s Manual
Destination Device
*1 Advanced mode only
Device: Use a word device.
Specify the device.
Click to display the Device Address Settings dialog box. For the device address configuration procedure,
refer to Chapter 2 “5.1 Device Address Settings” on page 2-62.
Use Reference Device
*1
:
Select this check box and specify a device to change the source word device according to
the value of the specified device.
This setting is enabled only if Action Mode is set to Move.
For details, refer to Chapter 2 “Indirect Read and Indirect Write Settings” on page 2-5.
Transfer
Specify the number of word devices (1 to 64) to move.
This setting is enabled only if Action Mode is set to Move.
Example: If Transfer is set to 2 and Write is set to 3, the same data in 2 continuous word
devices will be written to the destination device 3 times.
*1
:
Source Data (Device): LDR0
Write: 3
999LDR0
Destination Device: D100
D100
D101
D102
D103
Transfer: 2
1000LDR1
D104
D105
999
1000
999
1000
999
1000
Condition
Satisfied
Satisfied
Satisfied
Destination Device: Specify the destination word device.
Click to display the Device Address Settings dialog box. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-62.
Use Reference Device
*1
:
Select this check box and specify a device to change the destination word device
according to the value of the specified device.
This setting is enabled only if Action Mode is set to Move.
For details, refer to Chapter 2 “Indirect Read and Indirect Write Settings” on page 2-5.
Write
Specify the number of word devices (1 to 64) at the destination.
For Move, specify how many times to repeat writing.
This setting is enabled only if Action Mode is set to Set, Momentary, Alternate, or
Move.
Example: If Data Type is set to BIN16(+) and Write is set to 5, the same data will be
written to 5 continuous word addresses.
If Data Type is set to BIN32(+) and Write is set to 5, the same data will be
written to a total of 10 word addresses (2 words 5 times).
*1
:
Destination Device: LDR10
Write: 5
Data Type: BIN16(+)
Source Data (Value): 12345
12345LDR10
12345LDR11
12345LDR12
12345LDR13
12345LDR14
5 words
Condition
SatisfiedSatisfiedSatisfied
Destination Device: LDR10
Write: 5
Data Type: BIN32(+)
Source Data (Value): 987654
LDR10
987654
LDR11
LDR12
987654
LDR13
LDR14
987654
LDR15
LDR16
987654
LDR17
LDR18
987654
LDR19
2 words x 5
Condition
SatisfiedSatisfiedSatisfied

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals