EasyManuals Logo
Home>IDEC>Controller>SmartAXIS Touch FT1A Series

IDEC SmartAXIS Touch FT1A Series User Manual

IDEC SmartAXIS Touch FT1A Series
1232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #782 background imageLoading...
Page #782 background image
4 Using the Data
14-28 SmartAXIS Touch User’s Manual
Example 2
Copying three items of the newest data in the Data Log in order from the oldest to the destination device
Example 3
Setting the starting point to the fourth item of the oldest data in the Data Log and copying three items of data from
the newest to the destination device
Item Setting
Destination Device LDR10
Starting Point Newest Data
Number of Data 3
Stored Order of Data From Oldest to Newest
Data Log data
Sampling Time Value
Destination Device
Value
12/18/2011 17:44:10
20
Configured device
LDR10 24 Copy from oldest data
11RDL::
26
12/19/2011 19:24:43
21RDL22 28
12/19/2011 20:01:54
24
Newest data
read starting point
12/19/2011 21:39:21
26
12/20/2011 05:57:06
28
Amount of data: 3
Item Setting
Destination Device LDR10
Starting Point Specify by Value of Device (value is 4)
Number of Data 3
Stored Order of Data From Newest to Oldest
Data Log data
Sampling Time Value
Destination Device
Value
12/18/2011 17:44:10
20
Configured device
LDR10 28
Copy from newest data
Specify by Value of Device
read starting point
12/19/2011 07:24:09
11RDL12 26
12/19/2011 19:24:43
21RDL22 24
(Source device: 4)
12/19/2011 20:01:54
24
12/19/2011 21:39:21
26
12/20/2011 05:57:06
28
12/20/2011 15:26:17
29
12/21/2011 06:46:57
31
Amount of data: 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals