LASER UNIT
3-44
7. After installing the LD unit, execute SP2115 001~009 to input the pitch settings
for the main scan beams.
NOTE: The correct settings for these SP codes are printed on a decal attached
to the mounting bracket [C] of the LD unit.
The 9 numbers printed on the label correspond to the correct settings of the SP
codes shown in the diagram above.
Here is an example
-10/-2/+10/-100/+0/+100
-10/-10/-10
To enter these numbers, you would execute
SP2115 001
SP2115 002
SP2115 003
SP2115 004
SP2115 005
SP2115 006
• Press to enter the minus sign.
• Press after each entry.
• A key press is not required for the plus sign.
SP2115 007
SP2115 008
SP2115 009
CAUTION: This example is for instructional purposes only. When you do this
adjustment, you must enter the numbers printed on the label
attached to the LD unit.
8. Do SP2962 (Auto Process Control Execution).
9. Make some test copies and check that the magnification is correct. If not
correct, please do the printer copy adjustments. (3.15)
<LD Unit Lot No.>
SP2115 001/SP2115 002/SP2115 003/SP2115 004/SP2115 005/SP2115 006
SP2115 007/SP2115 008/SP2115 009
B234R901.WMF