SP4-nnn Scanner
4008 Scanner Sub Scan Magnification
Adjusts the magnification in the sub scan direction for scanning. If this value is
changed, the scanner motor speed is changed. (3-18)
[-0.9~+0.9 / 0 / 0.1 percent]
Use the “
•
/ *key to enter the minus ( –) before entering the value.
Setting a lower value reduces the motor speed and lengthens the image in the sub
scan direction (paper direction). Setting a larger value increases the motor speed and
shortens the image in the sub scan direction.
4010 Scanner Leading Edge Registration
Adjusts the leading edge registration for scanning. (3-18)
[-9.0~+9.0 / 0 / 0.1 mm]
Use the “
•
/ *key to enter the minus ( –) before entering the value.
A minus setting moves in the direction of the leading edge. A larger value shifts the
image away from the leading edge, and a smaller value shifts the image toward the
leading edge.
4011 Scanner Side-to-Side Registration
Adjusts the side-to-side registration for scanning. (3-18)
[-3.0~+3.0 / 0 / 0.1 mm]
(–): The image disappears at the left side.
(+): The image appears at the left side.
Use the “
•
/ *key to enter the minus ( –) before entering the value.
4012 Set Scale Mask
djusts the erase margin for scanning. The leading, trailing, right and left margins
can be set independently.
Do not adjust this unless the user wishes to have a scanner
margin that is greater than the printer margin.
[0~3.0 / 0.5 / 0.1 mm]
001
Sub:LEdge
Leading edge, sub scan direction
002
Sub:TEdge
Trailing edge, sub scan direction
003
Main:LEdge
Front, main scan direction
004
Main:TEdge
Back, main scan direction
4013 Scanner Free Run
001 Scanner Free Run: Lamp OFF
Allows scanner free running with exposure lamp
off.
002 Scanner Free Run: Lamp ON
Allows scanner free running with the exposure
lamp on.