Z-Folding Unit ZF4000 (B660)
SM 1-89 B234/B235/B236/D101/D102/D103
Installation
Connecting the Z-Folding Unit B660
1. Fasten brackets [A] (x2) (provided accessories) to the Cover Interposer Tray
B835 (or Copier) ( x 2 each).
2. Remove support screw and bracket [B], push in the support, then reattach the
screw and bracket
3. Pull the top cover [C] toward you then raise it.
4. Raise the horizontal transport plate [D] to the left.
5. Pull out the Z-folding mechanism [E].
6. Pull out the Z-folding unit lock lever [F] ( x 1).
7. At the right bottom edge of the Z-folding unit, confirm that the breaker switch is
ON.
NOTE: This switch should display “—”. If you see “O”, set the switch to “—”.
The machine will not recognize the Z-folding unit if this switch is off.
8. Dock the Z-folding unit to the cover interposer tray (or Copier).
9. Push in the lock lever [F] and fasten it ( x 1).
10. Push in the Z-folding mechanism [E], lower the horizontal transport plate [D],
then close the front door [C].
11. Connect the Z-Folding unit to the copier.
12. Connect the Z-Folding unit power cord to the Z-folding unit and connect the
other end of the cord to the power ac supply.
B660I007A.WMF
[A]
[B]
[C]
[D]
[E]
[F]