REPLACEMENT AND ADJUSTMENT
SM 5 B833
Multi Bypass
Tray
B833
1.4 FEED ROLLERS
1. Pull off the pick-up roller cover [A].
2. Pull off the separation roller cover [B].
3. Remove the pick-up roller [C] ( x 1).
4. Remove the feed roller [D] ( x 1).
5. Remove the separation roller [E] ( x 1).
NOTE: After re-installing the feed roller, make sure that it rotates clockwise.
6. Reset the PM count to zero for the new rollers.
B833R906.WMF
[A]
[B]
[C]
[D]
[E]