COPIER (B234/B235/B236/D101/D102/D103)
SM 1-19 B234/B235/B236/D101/D102/D103
Installation
Internal Tape and Retainers: Drum Cleaning Unit
1. Open the right front door.
2. Remove the black screws at n ( x3).
3. Take off the inner cover o.
NOTE: These illustrations show removal
using the hex driver provided to the customer.
This tool is not required for removal of these
screws. You can use a common Phillips head
(plus) screwdriver to remove these screws.
Important! This cover functions as a duct in
the ventilation path of the machine. It must be
reinstalled.
4. Remove the ground plate ( x1)
5. Remove the faceplate.
Lower C1 and remove the retainer ( x1).
Screw ( x)
Remove the knob.
1
1
1
2
B234i107.WMFF
B234I110E.WMF
1
3
2
B234I110.WMF