FUSING
SM 6-163 B234/B235/B236/D101/D102/D103
Detailed
Descriptions
6.16.7 FUSING PRESSURE
Fusing pressure is constantly applied between the hot roller [A] and pressure roller
[B] by the upper pressure lever [C] and lower pressure lever [D], which are lifted by
the fusing unit release lever [E] via the pressure cam [F]. The pressure can be
adjusted by using the pressure adjustment screw [G].
The fusing pressure is released by turning the fusing unit release lever
counterclockwise.
B234D989.WMF
B234D990.WMF
[E]
[A] [B]
[G]
[F]
[C]
[D]
[G]
[C]
[D]
[F]
[G]
[F]
[D]
[C]