EasyManua.ls Logo

Cisco AP775A - Nexus Converged Network Switch 5010 - Fcsp Reauthenticate

Cisco AP775A - Nexus Converged Network Switch 5010
792 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send comments to nx5000-docfeedback@cisco.com
8-73
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
fcsp reauthenticate
fcsp reauthenticate
To reauthenticate a Fibre Channel or virtual Fibre Channel interface, use the fcsp reauthenticate
command. Use the no form of the command to revert to factory defaults.
fcsp reauthenticate interface { fc slot/port | vfc vfc-id }
no fcsp reauthenticate interface { fc slot/port | vfc vfc-id }
Syntax Description
Command Default 30 seconds
Command Modes EXEC mode
Command History
Examples The following example configures the FCSP reauthentication on a virtual Fibre Channel interface:
switch# fcsp reauthenticate vfc 1
Related Commands
interface Specifies the interface on which to perform the reauthentication.
interface fc slot/port Specifies the Fibre Channel interface by slot and port number.
vfc vfc-id Specifies the virtual Fibre Channel interface by virtual interface group
number and virtual interface ID.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
fcsp enable Enable FC-SP.
show fcsp Displays configured FC-SP information.