EasyManuals Logo

Cisco AP775A - Nexus Converged Network Switch 5010 Command Reference

Cisco AP775A - Nexus Converged Network Switch 5010
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #737 background imageLoading...
Page #737 background image
Send comments to nx5000-docfeedback@cisco.com
9-29
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 9 Fibre Channel Show Commands
show flogi
show flogi
To list all the fabric login (FLOGI) sessions through all interfaces across all VSANs, use the show flogi
command.
show flogi {auto-area-list} | database {fcid fcid-id | interface {fc slot/port | vfc vfc-id} | vsan
vsan-id}
Syntax Description
Command Default None
Command Modes EXEC mode.
Command History
Usage Guidelines The output of this command is sorted by interface numbers and then by VSAN IDs.
In a Fibre Channel fabric, each host or disk requires an FCID. Use the show flogi database command
to verify if a storage device is displayed in the fabric login (FLOGI) table as in the examples below. If
the required device is displayed in the FLOGI table, the fabric login is successful. Examine the FLOGI
database on a switch that is directly connected to the host HBA and connected ports.
Examples The following example displays details on the FLOGI database:
switch# show flogi database
The following example displays the FLOGI interface:
switch# show flogi database interface fc 2/3
auto-area-list Displays the list of Organizational Unit Identifiers (OUIs) that are allocated
areas.
database Displays information about FLOGI sessions.
fcid fcid-id Displays FLOGI database entries based on the FCID allocated. The format
is 0xhhhhhh.
interface Displays FLOGI database entries based on the logged in interface.
fc slot/port Specifies the Fibre Channel or virtual Fibre Channel interface by slot and
port number.
vfc vfc-id Specifies a virtual Fibre Channel interface.
vsan vsan-id Displays FLOGI database entries based on the VSAN ID. The range is 1 to
4093.
Release Modification
4.0(0)N1(1a) This command was introduced.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals