8-90
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
interface fc
interface fc
To configure a Fibre Channel interface on a Cisco Nexus 5000 Series switch, use the interface fc
command. The interface fc command enters interface configuration mode, which includes five
commands (each with a no form).
To revert to defaults, use the no form of the command.
interface fc slot/port
channel-group {group-id [force] | auto}
fcdomain rcf-reject vsan vsan-id
fcsp {auto-active | auto-passive | on | off} [timeout-period]
fspf {cost link-cost vsan vsan-id | dead-interval seconds vsan vsan-id | hello-interval seconds
vsan vsan-id | passive vsan vsan-id | retransmit-interval seconds vsan vsan-id}
switchport
no interface fc slot/port
no channel-group {group-id [force] | auto}
no fcdomain rcf-reject vsan vsan-id
no fcsp {auto-active | auto-passive | on | off}
no fspf {cost link-cost vsan vsan-id | dead-interval seconds vsan
vsan-id | hello-interval
seconds vsan vsan-id | passive vsan vsan-id | retransmit-interval seconds vsan vsan-id}
switchport
Syntax Description
Command Default Disabled.
Command Modes Configuration mode
slot/port Specifies a slot number and port number.
channel-group Adds to or removes from a Port Channel.
group-id Specifies a Port Channel group number from 1 to 128.
force Forcefully adds a port.
auto Enables autocreation of port channels.
fcdomain Enters the interface mode.
rcf-reject Configures the rcf-reject flag.
vsan vsan-id Specifies the VSAN ID. The range is 1 to 4093.
fspf Configures FSPF parameters.
cost link-cost Configures FSPF link cost. The range is 1 to 65535.
dead-interval seconds Configures FSPF dead interval in seconds. The range is 2 to 65535.
hello-interval seconds Configures FSPF hello-interval. The range is 1 to 65535.
passive Enables or disables FSPF on the interface.
retransmit-interval
seconds
Configures FSPF retransmit interface in seconds. The range is 1 to 65535.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals