Send comments to nx5000-docfeedback@cisco.com
10-7
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 10 Vpc Commands
show vpc brief
id Port Status Consistency Reason Active vlans
-- ---- ------ ----------- -------------------------- ------------
20 Po20 up success success 1-100
This example also shows how to display brief information about the vPCs. In this example, the port
channel failed the consistency check, and the device displays the reason for the failure:
switch(config)# show vpc brief
Legend:
(*) - local vpc is down, forwarding via vPC peer-link
vPC domain id : 10
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: failed
Configuration consistency reason: vPC type-1 configuration incompatible - STP interface
port type inconsistent
vPC role : secondary
Number of vPC configured : 1
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po10 up 1-100
vPC status
----------------------------------------------------------------------
id Port Status Consistency Reason Active vlans
-- ---- ------ ----------- -------------------------- ------------
20 Po20 up failed vPC type-1 configuration -
incompatible - STP
interface port type
inconsistent
This example also shows how to display information about the tracked objects in the vPCs:
switch(config)# show vpc brief
Legend:
(*) - local vpc is down, forwarding via vPC peer-link
vPC domain id : 1
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
vPC role : secondary
Number of vPC configured : 3
Track object : 12
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po10 up 1-100