EasyManua.ls Logo

Cisco AP775A - Nexus Converged Network Switch 5010

Cisco AP775A - Nexus Converged Network Switch 5010
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send comments to nx5000-docfeedback@cisco.com
8-85
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
fspf enable
fspf enable
To enable FSPF for a VSAN, use the fspf enable command. To disable FSPF routing protocols, use the
no form of the command.
fspf enable vsan vsan-id
no fspf enable vsan vsan-id
Syntax Description
Command Default Enabled.
Command Modes Configuration mode
Command History
Usage Guidelines This command configures FSPF on VSANs globally.
Examples The following example enables FSPF in VSAN 5 and disables FSPF in VSAN 7:
switch(config)# fspf enable vsan 5
switch(config)# no fspf enable vsan 7
Related Commands
vsan vsan-id Specifies a VSAN ID. The range is 1 to 4093.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
fspf config vsan Configures FSPF features for a VSAN.
show fspf interface Displays information for each selected interface.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Related product manuals