8-85
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
fspf enable
fspf enable
To enable FSPF for a VSAN, use the fspf enable command. To disable FSPF routing protocols, use the
no form of the command.
fspf enable vsan vsan-id
no fspf enable vsan vsan-id
Syntax Description
Command Default Enabled.
Command Modes Configuration mode
Command History
Usage Guidelines This command configures FSPF on VSANs globally.
Examples The following example enables FSPF in VSAN 5 and disables FSPF in VSAN 7:
switch(config)# fspf enable vsan 5
switch(config)# no fspf enable vsan 7
Related Commands
vsan vsan-id Specifies a VSAN ID. The range is 1 to 4093.
Release Modification
4.0(0)N1(1a) This command was introduced.
Command Description
fspf config vsan Configures FSPF features for a VSAN.
show fspf interface Displays information for each selected interface.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals