8-140
Cisco Nexus 5000 Series Command Reference
OL-16599-01
Chapter 8 Fibre Channel Commands
vsan database
vsan database
To create multiple fabrics sharing the same physical infrastructure, assign ports to VSANs, turn on or
off interop mode, load balance either per originator exchange or by source-destination ID, and enter
VSAN database mode, use the vsan database command. To remove a configuration, use the no
command in VSAN database mode.
vsan database
vsan vsan-id
[interface {fc slot/port | san-port-channel port | vfc vfc-id} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
vsan database
no vsan vsan-id
[interface {fc slot/port | san-port-channel port | vfc vfc-id} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id |
src-dst-ox-id}]]
Syntax Description
Command Default None
vsan vsan-id Specifies the VSAN ID. The range is 1 to 4093.
interface fc slot/port (Optional) Specifies the Fibre Channel interface by slot and port number
on the switch.
san-port-channel
portchannel-number.
subinterface-number
Configures the SAN port channel interface specified by the SAN port
channel number followed by a dot (.) indicator and the subinterface
number.
vfc vfc-id Specifies the virtual Fibre Channel interface.
interop Turns on interoperability mode.
mode Specifies the interop mode. The range is 1 to 4.
loadbalancing Configures load-balancing scheme.
src-dst-id Sets src-id/dst-id for load-balancing.
src-dst-ox-id Sets ox-id/src-id/dst-id for load-balancing (default).
name name Assigns a name to the VSAN. Maximum length is 32 characters.
suspend Suspends the VSAN.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals