DES-1210-52/ME L2 Metro Ethernet Switch CLI Reference Guide
130
DES-1210-52/ME:5# disable cpu_protect
Command: disable cpu_protect
Success.
DES-1210-52/ME:5#
config cpu_protect type
Purpose
To configure the CPU protection packet type on the Switch.
Syntax
config cpu_protect type [arp | bpdu | icmp | igmp | snmp] pps
[<value> | no_limit]
Description
The config cpu_protect type command is used to configure the
CPU protection packet type on the Switch.
Parameters
[arp | bpdu | icmp | snmp] Specifies the packet type of CPU
protection to be configured.
[<value> | no_limit] Specifies the maximum packet number can be
up to CPU.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To configure the CPU protection with ARP type on the switch:
DES-1210-52/ME:5# config cpu_protect type arp pps no_limit
Command: config cpu_protect type arp pps no_limit
Success.
DES-1210-52/ME:5#