DES-1210-52/ME L2 Metro Ethernet Switch CLI Reference Guide
319
42
TIME AND SNTP COMMANDS
The Time and SNTP commands in the Command Line Interface (CLI) are listed (along with the
appropriate parameters) in the following table.
{primary [<ipaddr> | <ipv6addr>] | secondary [<ipaddr> | <ipv6addr>] | poll-
interval <sec 30-99999>}
config time_zone
operator
[+ hour <gmt_hour 0-13> minute <minute 0-59> | - hour <gmt_hour 0-12> minute
<minute 0-59>]
[disable | [annual s_date <start_date 1-31> s_mth <start_mth 1-12> s_time
<start_time> end_date <int 1-31> e_mth <end_mth 1-12> e_time <end_time> |
offset [30 | 60 | 90 | 120]]]
Each command is listed in detail, as follows:
config sntp {primary [<ipaddr> | <ipv6addr>] | secondary
[<ipaddr> | <ipv6addr>] | poll-interval <sec 30-99999>}
The config sntp command configures SNTP service from an SNTP
server. SNTP must be enabled for this command to function (See
enable sntp).
primary [<ipaddr>| <ipv6addr>] – Specifies the IPv4 or IPv6 address
of the primary SNTP server.
secondary [<ipaddr>| <ipv6addr>] – Specifies the IPv4 or IPv6
address of the secondary SNTP server.
poll-interval <sec 30-99999> – The interval between requests for
updated SNTP information. The polling interval ranges from 60
seconds (1 minute) to 86,400 seconds (1 day).
Only administrator or operate-level users can issue this command.
SNTP service must be enabled for this command to function (enable
sntp).
Example usage:
To configure SNTP settings: