DES-1210-52/ME L2 Metro Ethernet Switch CLI Reference Guide
150
--------- ----------------------- ----------- ------------ ------------- -----------
1 1.1.2.1 All Local0 514 Enabled
Total Entries : 1
DES-1210-52/ME:5#
To determine if there are any errors on the copper cables and the
position where the errors may have occurred.
cable diagnostic port [<portlist> | all]
The cable diagnostic port command is used to determine if there
are any errors on the copper cables and the position where the
errors may have occurred. Cable length is detected as following
range: <50m, 50~80, 80~100, >100m. Deviation is +/-5 meters,
therefore "No Cable" may be displayed under "Test Result," when
the cable used is less than 5 m in length. The Fault Distance will
show “No Cable”, whether the fiber is connected to the port or not.
<portlist> – A port or range of ports to be configured.
all − Specifies all ports on the Switch are to be configured.
Example usage:
To determine the copper cables and position of port 3 on the Switch:
DES-1210-52/ME:5# cable diagnostic port 3
Command: cable diagnostic port 3
Perform Cable Diagnostics ...
Port Type Link Status Test Result Fault Distance (meters) Length(M)
---- ----- --------------- ----------------- --------------------------------- ---------
3 FE Link Down Pair1:N/A Pair1:No Cable N/A
Pair2:OPEN Pair2:1
Pair3:N/A Pair3:N/A
Pair4:N/A Pair4:N/A
DES-1210-52/ME:5#
To configure the system login timeout.
config syslogintimeout <integer 3-30>
The config syslogintimeout command is used to configure the
system login timeout.
<integer 3-30> − Specify the system login time. The range is
between 3 and 30 minutes.