To enable unidirectional link detection on port 1:
DES-1210-52/ME:5# config duld ports 1 state enable
Command: config duld ports 1 state enable
Success.
DES-1210-52/ME:5#
show duld ports
Purpose
To show unidirectional link detection information.
Syntax
show duld ports {<portlist> | all}
Description
This show duld ports command is used to show unidirectional link
detection information.
Parameters
[<portlist> | all] Specifies a port, a range of ports or all ports to be
displayed.
Restrictions
None.
Example usage:
To show unidirectional link detection information of port 1:
DES-1210-52/ME:5# show duld ports 1
Command: show duld ports 1
port Admin State Oper Status Mode Link Status Discovery Time(Sec)
------ ------------------- ----------------- -------- ----------------- -------------------
1 Enabled Disabled Normal Unknown 10
DES-1210-52/ME:5#
config duld recover_timer
Purpose
To configure unidirectional link detection recover time.
Syntax
config duld recover_timer [0 | <sec 60-1000000>]
Description
The config duld recover_timer command is used to configure
unidirectional link detection recover time.
Parameters
[0 | <sec 60-1000000>] Specifies the recover time of unidirectional
link detection function.