| CFM Commands
– 1321 –
Basic Configuration Steps for CFM
1. Configure the maintenance domains with the ethernet cfm domain
command.
2. Configure the maintenance associations with the ma index name
command.
3. Configure the local maintenance end points (MEPs) which will serve as
the domain service access points for the specified maintenance
association using the ethernet cfm mep command.
4. Enter a static list of MEPs assigned to other devices within the same
maintenance association using the mep crosscheck mpid command.
This allows CFM to automatically verify the functionality of these
remote end points by cross-checking the static list configured on this
device against information learned through continuity check messages.
Link Trace Operations
ethernet cfm linktrace
cache
Enables caching of CFM data learned through link trace
messages
GC
ethernet cfm linktrace
cache hold-time
Sets the hold time for CFM link trace cache entries GC
ethernet cfm linktrace
cache size
Sets the maximum size for the link trace cache GC
ethernet cfm linktrace Sends CFM link trace messages to the MAC address for
a MEP
PE
clear ethernet cfm
linktrace-cache
Clears link trace messages logged on this device PE
show ethernet cfm
linktrace-cache
Displays the contents of the link trace cache PE
Loopback Operations
ethernet cfm loopback Sends CFM loopback messages to a MAC address for a
MEP or MIP
PE
Fault Generator Operations
mep fault-notify alarm-
time
Sets
the time a defect must exist before a fault alarm
is issued
CFM
mep fault-notify lowest-
priority
Sets the lowest priority defect that is allowed to
generate a fault alarm
CFM
mep fault-notify reset-
time
Configures the time after a fault alarm has been
issued, and no defect exists, before another fault
alarm can be issued
CFM
show ethernet cfm fault-
notify-generator
Displays configuration settings for the fault notification
generator
PE
Delay Measure Operations
ethernet cfm delay-
measure two-way
Sends periodic delay-measure requests to a specified
MEP within a maintenance association
PE
Table 177: CFM Commands (Continued)
Command Function Mode