◆ AIS Transmit Level – Configure the AIS maintenance level in an MA.
(Range: 0-7; Default is 0)
AIS Level must follow this rule: AIS Level >= Domain Level
◆ AIS Suppress Alarm – Enables/disables suppression of the AIS.
(Default: Disabled)
WEB INTERFACE
To create a maintenance association:
1. Click Administration, CFM.
2. Select Configure MA from the Step list.
3. Select Add from the Action list.
4. Select an entry from the MD Index list.
5. Specify the MAs assigned to each domain, the VLAN through which CFM
messages are passed, and the manner in which MIPs can be created
within each MA.
6. Click Apply.
Figure 301: Creating Maintenance Associations