7. Handset Menu System
7-32
7.8.1 Unit selection menu for Alarm Pack ( MENU+8)
OK
OK
7 Call Log
8 Alarmpack
01
01/JAN/2012
1 ADE*
2 BDE
3 MDM
BDE alarm display screen
Next Page
MDM alarm display screen
2 Page After
Fig. 7.8.1a Unit selection menu for Alarmpack
(ADE)
.Transmitting output
(dBw)
….ADE temperature (degree) *
.HPA temperature (degree)
.Satellite Azimuth
.Satellite Elevation
.Antenna Bearing
.Antenna Elevation
.Antenna Cross Elevation**
..Radio wave tracking-signal value*
..Radio wave step track signal value
..Satellite search status of ADE
.Position acquisition status of GPS
.GPS Heading value
.Maximum value of X vibration
for last 6 min.
…. Average value of X vibration
for last 6 min.
.Maximum value of Y vibration
for last 6 min.
…. Average value of Y vibration
for last 6 min.
EIRP:
15.0
ADE: +0.0
HPA: +45.0
Sat AZ: 173.5
Sat EL: 48.0
BR: 163.9
EL: +46.0
Cross EL:
-0.7
RSSl-1: 0
RSSl-2: 120
ADE Search:
2
GPS Status:
3D FIX
GPSHD: 0.0
Vib X Max:
+0.0
Vib X Ave:
+0.0
Vib Y Max:
+0.0
Vib Y Ave:
+0.0
OK
.Maximum value of Z vibration
for last 6 min.
…. Average value of Z vibration
for last 6 min.
.Maximum value of Rolling
for last 6 min.
…. Average value of Rolling
for last 6 min.
.Maximum value of Pitching
for last 6 min.
…. Average value of Pitching
for last 6 min.
..PLL Lock Detect
..Using Global beam
..Using WRF filter
..Using WRF Port
..WRF Monitor
..Tracking Mode
(Auto/ GpsHD/ Sensor)
Vib Z Max:
+0.0
Vib Z Ave:
+0.0
Rol Max:
+0.0
Rol Ave:
+0.0
Pit Max:
+0.0
Pit Ave:
+0.0
PLL LockDet:
ON
Global Beam:
242
A:0000000000
00
WRF Filter:
Narrow
WRF Port:
Disable
WRF Moni:
102
Track Mode:
Auto
Alarm bit display
(from left, displaying 1 means abnormal)
(1st line)
1. Axis control error
2. Acceleration sensor error
3. Rate sensor error
4. Memory error
5. Off power alarm
6. High power alarm
7. Burst error
8. Program error
9. Fan alarm
10. Internal GPS alarm
(2nd line)
11. External GPS alarm
(Cold Start or Unfix)
12. PLL lock error
* is fixed to 0 for JUE-501 and JUE-251.
** is fixed to 0 for JUE-251.
1.ADE alarm display screen