[SENSe:]CORRection:CKIT:LCATalog?...........................................................................1126
[SENSe:]CORRection:CKIT:LDELete..............................................................................1126
[SENSe:]CORRection:CKIT:LLABel................................................................................1126
[SENSe:]CORRection:CKIT:LSELect..............................................................................1127
[SENSe:]CORRection:CKIT:STANdard:LCATalog?...........................................................1128
[SENSe:]CORRection:CKIT:<ConnType>:LSELect.......................................................... 1128
[SENSe:]CORRection:CKIT:<StandardType>:WLABel......................................................1129
[SENSe:]CORRection:CKIT:<OnePortStandardType>:WLABel:SDATa?............................. 1129
[SENSe:]CORRection:CKIT:<TwoPortStandard>:WLABel:SDATa?.................................... 1130
[SENSe:]CORRection:CKIT:LCATalog? [<ConnectorType>]
Returns a list of all cal kits and their labels for a given connector type or for all connec-
tor types.
Query parameters:
<ConnectorType> Name of the connector type. Use [SENSe<Ch>:
]CORRection:CONNection:CATalog? to query connector
names.
If omitted, the command returns the list of all cal kits andlabels.
Example: See [SENSe<Ch>:]CORRection:CONNection:CATalog?
Usage: Query only
[SENSe:]CORRection:CKIT:LDELete <CalKitName>, <KitLabel>
Deletes an imported or user-defined cal kit which is identified by its cal kit name and
label.
Note: It is not possible to modify or store predefined or ideal kits.
Setting parameters:
<CalKitName> String parameter containing an imported or user-defined calibra-
tion kit available on the analyzer.
<KitLabel> String parameter containing the label of an imported or user-
defined calibration kit available on the analyzer.
Example: See [SENSe:]CORRection:CKIT:LLABel
Usage: Setting only
[SENSe:]CORRection:CKIT:LLABel <CalKitName>, <KitLabel>[, <NewKitLabel>]
Assigns a calibration kit label to an imported or user-defined calibration kit or renames
an existing calibration kit label.
Parameters:
<CalKitName> String parameter containing an imported or user-defined calibra-
tion kit available on the analyzer.
<KitLabel> String parameter containing the current calibration kit label.
SCPI Command Reference

Table of Contents

Related product manuals