EasyManua.ls Logo

R&S ZNB - 8.3.1.20 CALCulate:TRANsform...

R&S ZNB
1496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
926User Manual 1173.9163.02 ─ 55
Manual operation: See "TD-VSWR" on page 319
8.3.1.20 CALCulate:TRANsform...
The CALCulate:TRANsform... commands convert measured data from one repre-
sentation to another and control the transformation into the time domain (see Chap-
ter 5.7.2, "Time Domain Analysis", on page 201).
CALCulate<Chn>:TRANsform:COMPlex.......................................................................... 926
CALCulate<Chn>:TRANsform:IMPedance:RNORmal........................................................ 927
CALCulate<Chn>:TRANsform:TIME[:TYPE]..................................................................... 927
CALCulate<Chn>:TRANsform:TIME:CENTer.................................................................... 928
CALCulate<Chn>:TRANsform:TIME:DCHebyshev............................................................ 928
CALCulate<Chn>:TRANsform:TIME:LPASs......................................................................929
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam.....................................................929
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:CONTinuous................................. 930
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate................................ 930
CALCulate<Chn>:TRANsform:TIME:LPFRequency........................................................... 931
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor.................................................. 931
CALCulate<Chn>:TRANsform:TIME:SPAN....................................................................... 931
CALCulate<Chn>:TRANsform:TIME:STARt...................................................................... 932
CALCulate<Chn>:TRANsform:TIME:STATe...................................................................... 932
CALCulate<Chn>:TRANsform:TIME:STIMulus..................................................................933
CALCulate<Chn>:TRANsform:TIME:STOP.......................................................................933
CALCulate<Chn>:TRANsform:TIME:WINDow...................................................................933
CALCulate<Chn>:TRANsform:TIME:XAXis.......................................................................934
CALCulate<Chn>:TRANsform:COMPlex <Result>
Converts S-parameters into converted (matched-circuit) Y-parameters or Z-parameters
and vice versa, assuming that port no. i is terminated with Z
0i
so that the three parame-
ter sets are equivalent and the following formulas apply:
ii
ii
iii
S
S
ZZ
1
1
0
,,2
00
00
jiZZ
S
ZZ
Z
ji
ij
ji
ij
ii
ii
ii
i
ii
Z
S
S
Z
Y /1
1
11
0
99...,,1,,,/1
2
0000
jijiZ
ZZSZZ
S
Y
ij
jiijji
ij
ij
SCPI Command Reference

Table of Contents