338User Manual 1173.9163.02 ─ 55
The exported complex trace values are the values at the beginning of the trace
data flow. None of the following stages (trace mathematics, shift, time domain gate,
trace formatting and smoothing) affects the exported data. "Save" writes the raw
stimulus values (frequency/power/time, according to the sweep type) and the raw,
complex measurement points to a file. See Chapter 5.1.5, "Data Flow", on page 89.
Export of complex data is available for all trace file types.
Check box selected (on): Export the values as they are displayed in the diagram,
e.g. export the dB magnitude, if trace format "dB Mag" is selected. The trace file
does not necessarily contain the full (complex) information about the trace.
For trace formats involving Cartesian diagrams (dB Mag, Real, Imag...), the stimu-
lus value and a single real response value is exported. For circular diagrams, both
the real and imaginary part of the response value is exported.
The trace values are the fully processed values as they appear in the diagram
area. They correspond to the results in the marker info field. All possible stages of
the trace data flow (e.g. trace formats, trace mathematics, time domain transform,
shift, smoothing) are taken into account. Some trace functions (e.g. time scale,
shift stimulus) also affect the stimulus values.
Export of formatted data is not available for Touchstone files.
Field Separator
For ASCII (*.csv) or Matlab (*.dat) files only: Defines the separator that the ana-
lyzer uses to separate different numbers in each line of the file.
Decimal Separator
For ASCII (*.csv) files only: Selects either the "Point" or the "Comma" (if needed to
process the exported data with an external application) as a separator for decimal
numbers.
Save
Stores the trace data, according to the selected options.
Tip: Note the conditions described in "Conditions for Touchstone file export"
on page 142.
Remote command:
MMEMory:STORe:TRACe:PORTs
MMEMory:STORe:TRACe
MMEMory:STORe:TRACe:CHANnel
Comment Added to File
Defines a comment to be added to (the comment section of the) exported trace file.
If empty (←"Delete"), no comment will be added.
Remote command:
MMEMory:STORe:TRACe:OPTion:COMMent
6.5.11.3 Select Parameter Dialog
The "Select Parameter" dialog provides a selection of measurement results (e.g. S-
parameters) or traces, e.g. for trace import, import of power correction coefficients, limit
line import.
Trace Config Softtool

Table of Contents