Remote Control
R&S
®
ZNB/ZNBT
768User Manual 1173.9163.02 ─ 55
Bit No. Meaning
0 Operation Complete
This bit is set on receipt of the command *OPC after all previous commands have been
executed.
2 Query Error
This bit is set if either the controller wants to read data from the instrument without having
sent a query, or if it does not fetch requested data and sends new instructions to the instru-
ment instead. The cause is often a query which is faulty and hence cannot be executed.
3 Device-Dependent Error
This bit is set if a device-dependent error occurs. An error message with a number
between –300 and –399 or a positive error number, which describes the error in greater
detail, is entered into the error queue. See also Chapter 10, "Error Messages and Trouble-
shooting", on page 1417.
4 Execution Error
This bit is set if a received command is syntactically correct, but cannot be performed for
other reasons. An error message with a number between –200 and –300, which describes
the error in greater detail, is entered into the error queue.
5 Command Error
This bit is set if a command which is undefined or syntactically incorrect is received. An
error message with a number between -100 and -200, which describes the error in greater
detail, is entered into the error queue.
6 User Request
This bit is set when the instrument is switched over to manual control or when a user-
defined softkey is used (see SYSTem:USER:KEY).
7 Power On (supply voltage on)
This bit is set when the instrument is switched on.
Related common commands
The Event Status Register (ESR) can be queried using ESR?. The Event Status Enable
(ESE) register can be set using the command *ESE and read using *ESE?.
See also Common Commands.
7.5.3.4 STATus:OPERation
The STATus:OPERation register contains conditions which are part of the instrument's
normal operation. The analyzer does not use the STATus:OPERation register.
7.5.3.5 STATus:QUEStionable
The STATus:QUEStionable register indicates whether the acquired data is of ques-
tionable quality and monitors hardware failures of the analyzer. It can be queried using
the commands STATus:QUEStionable:CONDition? or
STATus:QUEStionable:EVENt?.