Command Reference
R&S
®
ZNB/ZNBT
1056User Manual 1173.9163.02 ─ 55
NONE - print no diagram at all.
*RST: n/a (*RST does not affect the printer configuration)
Example:
HCOP:PAGE:WIND SING; :HCOP
Select one diagram per page and start printing.
8.3.8 INITiate Commands
The INITiate... commands control the initiation of the trigger system and define
the scope of the triggered measurement.
INITiate[:IMMediate]:ALL...............................................................................................1056
INITiate:CONTinuous:ALL.............................................................................................1056
INITiate<Ch>[:IMMediate][:DUMMy]...............................................................................1057
INITiate<Ch>[:IMMediate]:SCOPe................................................................................. 1057
INITiate<Ch>:CONTinuous............................................................................................1057
INITiate[:IMMediate]:ALL
Starts a new single sweep sequence in all channels. This command is available in sin-
gle sweep mode only (INITiate:CONTinuous:ALL OFF). The data of the last sweep
(or of previous sweeps, see Retrieving the Results of Previous Sweeps) can be read
using CALCulate<Chn>:DATA:NSWeep:FIRSt? SDATa, <count>.
This command is not supported in the "ZVR" or "ZVABT" compatibility modes.
Note: In contrast to all other commands of the analyzer, the
INITiate<Ch>[:IMMediate]... commands have been implemented for overlap-
ped execution; see Chapter 7.4, "Command Processing", on page 758.
Example:
See INITiate<Ch>:CONTinuous
Usage: Event
Manual operation: See "Restart Sweep" on page 411
INITiate:CONTinuous:ALL <Boolean>
Qualifies whether the analyzer measures in single sweep or in continuous sweep
mode.
This command is not supported in the "ZVR" or "ZVABT" compatibility modes.
Parameters:
<Boolean> ON - the analyzer measures continuously in all channel, repeat-
ing the current sweep. The query returns ON (1) if at least one
channel is measured continuously.
OFF - the measurement is stopped after the number of sweeps
defined via [SENSe<Ch>:]SWEep:COUNt. INITiate<Ch>[:
IMMediate][:DUMMy] initiates a new measurement cycle.
*RST: ON