Command Reference
R&S
®
ZNB/ZNBT
833User Manual 1173.9163.02 ─ 55
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure
For a fixture modeling with the SFD tool, this command starts the measurement of the
coupon at the active ports (see CALCulate:FMODel:SFD<Ph_pt>:COUPon[:
STATe]).
The coupon type can be selected using CALCulate:FMODel:SFD<Ph_pt>:
COUPon:TYPE.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Usage: Event
Manual operation: See "Measure / Measure Open / Measure Short" on page 592
CALCulate:FMODel:SFD<Ph_pt>:COUPon:MEASure:FILename <String>
For a fixture modeling with the SFD tool, this command loads the coupon properties
from a Touchstone file.
The coupon type can be selected using CALCulate:FMODel:SFD<Ph_pt>:
COUPon:TYPE.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<String> Path to the Touchstone file, either absolute or relative to the cur-
rent directory (see MMEMory:CDIRectory)
Manual operation: See "Load File / 1x Open Preset / 1x Short Preset " on page 593
CALCulate:FMODel:SFD<Ph_pt>:COUPon:TYPE <CouponType>
Sets/gets the coupon type to be measured for a fixture modelling with the SFD tool.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<CouponType> SYMMetric2x | OPEN1x | SHORt1x
Manual operation: See "Coupon Type" on page 592
CALCulate:FMODel:SFD<Ph_pt>:COUPon[:STATe] <Boolean>
For a fixture modeling with the SFD tool, this command allows to specify the ports to
which the test coupon is connected.
This has to be defined before measuring the test coupon (using CALCulate:FMODel:
SFD<Ph_pt>:DUT:MEASure).
SCPI Command Reference