DEVELOPMENT AND TONER SUPPLY
3-68
4. Remove the entrance seal [A] ( x2) and clean it.
5. Clean the side seals [B].
Important: Handle the side seal carefully to avoid twisting or bending it.
6. Clean the development sleeves.
7. If you are installing a new development unit, go to the next step.
–or-
If you are only replacing the developer, clean the doctor blade before you pour
in the developer (3.8.4).