MAIN SERVICE PROGRAM MODE TABLES
B234/B235/B236/D101/D102/D103 5-60 SM
5513 Parts Alarm Level Count Japan Only
001 Normal
Sets the parts replacement alarm counter to sound for the number of copies.
[1~9999 / 350 / 1]
002 DF
Sets the parts replacement alarm counter to sound for the number of scanned
originals.
[1~9999 / 350 / 1]
5514 Parts Alarm Level Japan Only
001 Normal [0~1 / 1 / 1]
002 DF [0~1 / 0 / 1]
5515 SC/Alarm Setting
With NRS (New Remote Service) in use, these SP codes can be set to issue an SC
call when an SC error occurs. If this SP is switched off, the SC call is not issued when
an SC error occurs.
001 SC Call
002 Near End Call
003 End Call
[0~1/1/1]
0: Off
1: On
004 User Call
005 Not Used
006 TX Test
007 Device Information
008 Alarm
009 Illegal Toner
[0~1/1/1]
010 Auto Order Supplies
011 Supply Management Report
[0~1/0/1]
012 Jam/Door Open [0~1/1/1]
5516 Individual PM Alarm Call
This SP sets an alarm to send a notice to the service center when one of the seven
service parts covered by the TCRU replacement procedures has reached the end
or near end of service life.
Note:
The service parts covered in the TCRU replacement procedures are: 1)
development unit, 2) pre-charge unit, 3) charge unit, 4) drum cleaning unit, 5) PCU,
6) fusing unit, 7) fusing cleaning unit
001 Disable/Enable Setting (0:Not Send 1:Send) This SP switches this feature on/off.
Default 0: Not send.
002 Alarm Flag (0: Ready 1: Already Sent) Displays the status of the most recent
alarm.
003 Alarm Flag Clear [Execute] Clears the most recent alarm.