Siemens SINAMICS G120D - p0634[0...n] Q flux flux constant unsaturated; PSIQ KPSI UNSAT; p0635[0...n] Q flux quadrature axis current constant unsaturated; PSIQ KIQ UNSAT; p0636[0...n] Q flux direct axis current constant unsaturated; PSIQ KID UNSAT; p0637[0...n] Q flux flux gradient saturated; PSIQ Grad SAT

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-107
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
The parameter weights the unsaturated component of the quadrature axis flux function.
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the quadrature axis current.
Dependency: Refer to: p0634
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the direct axis current.
Dependency: Refer to: p0634
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the gradients of the saturated component over the quadrature axis current.
Dependency: Refer to: p0634, p0635, p0636
Description: Sets the current limit.
Dependency: Refer to: r0209, p0323
Note: The parameter is part of the quick commissioning (p0010 = 1); this means that it is appropriately pre-assigned when
changing p0305. The current limit p0640 is limited to r0209.
p0634[0...n] Q flux flux constant unsaturated / PSIQ KPSI UNSAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.000 [Vsrms] 100.000 [Vsrms] 0.000 [Vsrms]
p0635[0...n] Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p0636[0...n] Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p0637[0...n] Q flux flux gradient saturated / PSIQ Grad SAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [mH] 10000.00 [mH] 0.00 [mH]
p0640[0...n] Current limit / Current limit
Access level: 2 Calculated: p0340 = 1 Data type: FloatingPoint32
Can be changed: C(1, 3), U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 5722, 6640
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]