1.5.3 Parameters with "KHP_ACTIVE_READ"
The following list contains the parameters with the "KHP_ACTIVE_READ" attribute.
These parameters can also be read with activated know-how protection.
Product: SINAMICS G120D, Version: 4601800, Language: eng, Type: KHP_ACTIVE_READ
p0015 Macro drive unit / Macro drv unit
p0100 IEC/NEMA mot stds / IEC/NEMA mot stds
p0170 Number of Command Data Sets (CDS) / CDS count
p0180 Number of Drive Data Sets (DDS) / DDS count
p0199[0...24] Drive object name / DO name
p0300[0...n] Motor type selection / Mot type sel
p0304[0...n] Rated motor voltage / Mot U_rated
p0305[0...n] Rated motor current / Mot I_rated
p0400[0...n] Encoder type selection / Enc_typ sel
p0505 Selecting the system of units / Unit sys select
p0595 Technological unit selection / Tech unit select
p0730 BI: CU signal source for terminal DO 0 / CU S_src DO 0
p0731 BI: CU signal source for terminal DO 1 / CU S_src DO 1
p0806 BI: Inhibit master control / PcCtrl inhibit
p0922 PROFIdrive PZD telegram selection / PZD telegr_sel
p1080[0...n] Minimum speed / n_min
p1082[0...n] Maximum speed / n_max
p1520[0...n] CO: Torque limit upper / M_max upper
p2000 Reference speed reference frequency / n_ref f_ref
p2001 Reference voltage / Reference voltage
p2002 Reference current / I_ref
p2003 Reference torque / M_ref
p2005 Reference angle / Reference angle
p2006 Reference temp / Ref temp
p2007 Reference acceleration / a_ref
p2030 Field bus int protocol selection / Field bus protocol
p2038 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
p2079 PROFIdrive PZD telegram selection extended / PZD telegr ext
p7763 KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
p7764[0...n] KHP OEM exception list / KHP OEM excep list
p9601 SI enable functions integrated in the drive (processor 1) / SI enable fct P1
p9810 SI PROFIsafe address (processor 2) / SI PROFIsafe P2