Description: Setting parameter for the run-time group in which instance LVM 1 of the double-sided limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LVM 1 within the run-time group set in p20282.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance DIF 0 of the differentiating element.
Description: Sets the differentiating time constant Td in milliseconds of instance DIF 0 of the differentiating element.
Description: Display parameter for output quantity Y of instance DIF 0 of the differentiating element.
p20282 LVM 1 run-time group / LVM 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
5 9999 9999
p20283 LVM 1 run sequence / LVM 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
0 7999 730
p20284 CI: DIF 0 input X / DIF 0 input X
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - 0
p20285 DIF 0 differentiating time constant in ms / DIF 0 T_diff ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
0.00 340.28235E36 0.00
r20286 CO: DIF 0 output Y / DIF 0 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - -