Siemens SINAMICS G120D - r1970[0...1] Speed_ctrl_opt vibration test vibration frequency determined; n_opt f_vib det; r1973 Rotating measurement encoder test pulse number determined; n_opt puls no. det; p1974 Speed_ctrl_opt saturation characteristic maximum rotor flux; n_opt rotflux_max; r1979.0...11 BO: Speed_ctrl_opt status; n_opt status

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-247
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Dependency: IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1959
Refer to: F07984
Description: Displays the vibration frequencies determined by the vibration test.
Index: [0] = Frequency low
[1] = Frequency high
Dependency: Refer to: p1959
Refer to: F07985
Description: Displays the number of pulses determined during the vibration test.
Note: A negative signal indicates an incorrect polarity of the encoder signal.
Description: Sets the maximum flux setpoint to measure the saturation characteristic.
Description: Displays the status to check and monitor the states of speed controller optimization.
r1970[0...1] Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vib det
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r1973 Rotating measurement encoder test pulse number determined / n_opt puls no. det
Access level: 3 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p1974 Speed_ctrl_opt saturation characteristic maximum rotor flux / n_opt rotflux_max
Access level: 4 Calculated: p0340 = 1 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
104 [%] 120 [%] 120 [%]
r1979.0...11 BO: Speed_ctrl_opt status / n_opt status
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Speed controller optimization activated Yes No -
01 Speed controller optimization completed Yes No -
02 Speed controller optimization interrupted Yes No -
04 Encoder test active Yes No -
05 Saturation char. identification active Yes No -
06 Moment of inertia identification active Yes No -
07 Recalc. speed controller parameters active Yes No -
08 Speed controller vibration test active Yes No -