Siemens SINAMICS G120D - p2610 EPOS search for ref. tol. bandwidth for distance to zero mark; Tol_band to ZM; p2611 EPOS search for reference approach velocity reference point; v_appr ref_pt; p2612 BI: EPOS search for reference reference cam; Ref_cam; p2613 BI: EPOS search for reference reversing cam minus; Rev minus

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-347
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Dependency: Refer to: p2595, p2597, p2604, p2607, p2608, p2610
Refer to: F07459
Description: Sets the tolerance bandwidth for the distance to the zero mark
The zero mark is evaluated within the maximum distance between the reference cam and zero mark (p2609) minus
the tolerance bandwidth for the distance to the zero mark (p2610).
Dependency: Refer to: p2609
Description: Sets the approach velocity after detecting the zero mark to approach the reference point.
Dependency: Refer to: p2595, p2597, p2604, p2607, p2609, p2610
Note: When traversing to the reference point, the velocity override is not effective.
Description: Sets the signal source for the reference cam.
Dependency: Refer to: p2607
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency: Refer to: p2614
Note: If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2610 EPOS search for ref. tol. bandwidth for distance to zero mark / Tol_band to ZM
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
0 [LU] 2147482647 [LU] 2147482647 [LU]
p2611 EPOS search for reference approach velocity reference point / v_appr ref_pt
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
1 [1000 LU/min] 40000000 [1000 LU/min] 300 [1000 LU/min]
p2612 BI: EPOS search for reference reference cam / Ref_cam
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 0
p2613 BI: EPOS search for reference reversing cam minus / Rev minus
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 1