Siemens SINAMICS G120D - p1758[0...n] Motor model changeover delay time closed;open-loop control; MotMod t cl_op; p1759[0...n] Motor model changeover delay time open;closed-loop control; MotMod t op_cl; p1760[0...n] Motor model with encoder speed adaptation Kp; MotMod wE n_ada Kp; p1761[0...n] Motor model with encoder speed adaptation Tn; MotMod wE n_ada Tn

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-227
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the minimum time for falling below the changeover speed when changing from closed-loop controlled opera-
tion to open-loop controlled operation.
Dependency: Refer to: p1755, p1756
Description: Sets the minimum time for a transition from open-loop controlled to closed-loop controlled operation after the lower
changeover speed p1755 * (1 - p1756 / 100 %) has been exceeded.
Dependency: Refer to: p1755, p1756
Note: With p1759 = 2000 ms, the delay time becomes ineffective and the model changeover is determined by the output
frequency only (changeover for p1755).
Description: Sets the proportional gain of the controller for speed adaptation with encoder
Description: Sets the integral-action time of the controller for speed adaptation with encoder
Description: Induction motor (ASM):
Displays the referred imaginary system deviation for the adaptation circuit of the motor model.
Permanent magnet synchronous motor (PEM):
Displays the system deviation for speed adaptation.
r1762[0]: Angular deviation [rad-el] of the estimated EMF.
r1762[1]: Angular deviation [rad-el] of the low-level signal response for pulse technique.
p1758[0...n] Motor model changeover delay time closed/open-loop control / MotMod t cl_op
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
100 [ms] 10000 [ms] 500 [ms]
p1759[0...n] Motor model changeover delay time open/closed-loop control / MotMod t op_cl
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 [ms] 2000 [ms] 0 [ms]
p1760[0...n] Motor model with encoder speed adaptation Kp / MotMod wE n_ada Kp
Access level: 3 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.000 100000.000 1000.000
p1761[0...n] Motor model with encoder speed adaptation Tn / MotMod wE n_ada Tn
Access level: 3 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 [ms] 1000 [ms] 4 [ms]
r1762[0...1] Motor model deviation component 1 / MotMod dev comp 1
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 6721, 6730, 6731
Min Max Factory setting
- - -