Parameters
List of parameters
1-330
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the positioning monitoring time for the positioning monitoring.
After the positioning monitoring time expires, it is checked once as to whether the difference between the setpoint
and actual position lies within the positioning window and if required an appropriate fault is output.
Dependency: Refer to: p2543, p2544, r2684
Refer to: F07451
Note: The following applies for the setting of the standstill and positioning monitoring time:
Standstill monitoring time (p2543) <= positioning monitoring time (p2545)
Description: Sets the tolerance for the dynamic following error monitoring.
If the dynamic following error (r2563) exceeds the selected tolerance, then an appropriate fault is output.
Value = 0 --> The dynamic following error monitoring is de-activated.
Dependency: Refer to: r2563, r2684
Refer to: F07452
Note: The tolerance bandwidth is intended to prevent the dynamic following error monitoring incorrectly responding due to
operational control sequences (e.g. during load surges).
Description: Sets the cam switching position 1.
Dependency: Refer to: p2548, r2683
Caution: Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note: Position actual value <= cam switching position 1 --> r2683.8 = 1 signal
Position actual value > cam switching position 1 --> r2683.8 = 0 signal
Description: Sets the cam switching position 2.
Dependency: Refer to: p2547, r2683
p2545 LR positioning monitoring time / t_pos_monit
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4020
Min Max Factory setting
0.00 [ms] 100000.00 [ms] 1000.00 [ms]
p2546[0...n] LR dynamic following error monitoring tolerance / s_delta_monit tol
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 4025
Min Max Factory setting
0 [LU] 2147483647 [LU] 1000 [LU]
p2547 LR cam switching position 1 / Cam position 1
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4025
Min Max Factory setting
-2147483648 [LU] 2147483647 [LU] 0 [LU]
p2548 LR cam switching position 2 / Cam position 2
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4025
Min Max Factory setting
-2147483648 [LU] 2147483647 [LU] 0 [LU]