Siemens SINAMICS G120D - p20197 RSR 1 run sequence; RSR 1 RunSeq; p20198[0...3] BI: DFR 0 inputs; DFR 0 inputs; r20199 BO: DFR 0 output Q; DFR 0 output Q; r20200 BO: DFR 0 inverted output QN; DFR 0 inv outp QN

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-502
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance RSR 1 within the run-time group set in p20196.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for trigger input I, D input D, set input S, and reset input R of instance DFR 0 of the D flipflop.
Index: [0] = Trigger input I
[1] = D input D
[2] = Set S
[3] = Reset R
Description: Display parameter for output Q of instance DFR 0 of the D flipflop.
Description: Display parameter for the inverted output QN of instance DFR 0 of the D flipflop.
p20197 RSR 1 run sequence / RSR 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
0 7999 530
p20198[0...3] BI: DFR 0 inputs / DFR 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - 0
r20199 BO: DFR 0 output Q / DFR 0 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
r20200 BO: DFR 0 inverted output QN / DFR 0 inv outp QN
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -