Description: Setting parameter for the run sequence of instance BSW 1 within the run-time group set in p20216.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 0 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
Description: Sets the signal source of the switch setting I of instance NSW 0 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 0 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 0 of the numeric changeover switch is to be
called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20217 BSW 1 run sequence / BSW 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 7999 590
p20218[0...1] CI: NSW 0 inputs / NSW 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
p20219 BI: NSW 0 switch setting I / NSW 0 sw_setting
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20220 CO: NSW 0 output Y / NSW 0 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20221 NSW 0 run-time group / NSW 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
5 9999 9999